50 ohm 1/4" Super Flexible Feeder Cable (Flame retardant)
Product Description
Inner conductor | copper clad aluminum | φ 1.90mm |
Insulation | Foamed polyethylene | φ 4.70mm |
Outer conductor | Helical corrugated copper tube | φ 6.40mm |
Jacket | Flame retardant balck PE | φ 7.50mm |
50 ohm 1/4" super flexible feeder cable (Flame retardant) feature a lower VSWR, perfect shielding effectiveness, and extraordinary inter-modulation performance, these lead to fewer energy loss and outer interference. Morever, its high-performance of attenuation allows coaxial cable to be used in different RF systems, such as 3g, 4g mobile communication. And it have a wide range of applications, such as indoor distribution, broadcast, various base stations, wireless cellular, and others.
Mechanical Properties
Min. single bending radius | 25 mm |
Min. reapeted bending radius | 30 m |
Max.tensile force | 680N |
Recommended maximum clamp spacing | 1m |
Electrical properities
Characteristic impedance | 50±1 Ω |
Nominal capacitance | 79 pF/m |
Nominal inductance | 0.19 μh/m |
Propagation velocity | 82 % |
DC breakdown voltage | 1.6 kv |
Minmum insulation resistance | > 5000 MΩ·km |
Peak power rationg | 6 k |
Cut-off frequency | 20 Ghz |
Screening attenuation | >120 dB |
PIM | ≤-160 dBc@(2×20w) |
VSWR
690-960MHz | ≤ | 1.12 |
1700-2200MHz | ≤ | 1.12 |
2300-2400MHz | ≤ | 1.12 |
2500-2690MHz | ≤ | 1.15 |
Transmission properties
Frequency MHz | Attenuation @20℃,dB/100m(dB/100ft | Power @20℃,kW |
100 | 5.89(1.80) | 1.23 |
450 | 12.8(3.90) | 0.57 |
690 | 16.07(4.90) | 0.48 |
800 | 17.40(5.30) | 0.42 |
900 | 18.40(5.61) | 0.40 |
1000 | 19.60(5.98) | 0.37 |
1800 | 26.90(8.20) | 0.27 |
2000 | 28.50(8.69) | 0.26 |
2200 | 29.98(9.14) | 0.24 |
2400 | 31.43(9.58) | 0.23 |
2500 | 32.15(9.80) | 0.22 |
2600 | 32.86(10.02) | 0.22 |
2700 | 33.56(10.23) | 0.21 |
3000 | 35.60(10.85) | 0.20 |
※ Attenuation values may be with a tolerance of 5%.
Environmental properties
Flame retardant | IEC 60332-1, IEC60332-3C,UL CM |
2011/65EU(ROHS) | compliant |
Note: According to customers' requirements, the flame retardant of cable can meet or all of the standard of IEC 60332-1, IEC60332-3C,UL CMR.