N Male to N Female RF Surge Protector up to 3GHz
N type surge protectors are designed to be installed between outdoor antennas and sensitive radio equipment to protect equipment, structures and personnel from high-energy electrical pulses carried through the coax cable either from a direct lightning strike or induced by a nearby strike.
Surge protectors should be installed as close a possible to the equipment to be protected, often at the point where the coax cable enters the building. They can also be installed near the antenna for additional protection.HDG Telecom RF gas discharge tube lightning surge arrester with high quality provide excellent lightning protection and outstanding RF performance.
Interface | |
Application Standard | JIS C 5419 |
Electrical | |
Impedance | 50 ohm |
Frequency | DC-3GHz |
VSWR | ≤1.2:1 |
Insertion Loss | ≤0.3dB/3G |
Maximum Power | 250W/300MHz、160W/3500MHz、100W/900MHz 75W/1.2GHz、52W/1.9GHz、42W/2.4GHz、 36W/3GHz |
Insulation Resident | DC 100V more than 50 ohm |
Discharge Voltage(V) | 230±20% |
Initial Impulse Wave Discharge Voltage | Less than 700V 1KV/μ SEC |
Rated Impulse Wave Discharge | 10 (kA@8/20μ) 5 times |
Ground Connection | By feedthrough or screw terminal |
Mechanical | |
Temperature range | -30℃~+85℃ |
Rosh-compliance | Full ROHS compliance |
Watertightness(1 m,1 hour) | IP67 |
Material | |
Body | Brass / Ni plating |
Center conductor | Tin phosphor bronze / Ag or Au plating |
Insulator | PTFE |
Gasket | Silicone rubber |
Other | Brass / Ni plating |
Applications:
|